High-precision measurement technology with convenient smartphone operation, In the kit: 2 x testo 115i clamp thermometers, 2 x testo 549i high-pressure gauges, testo HVAC softcase, In the kit: 2 x testo 115i clamp thermometers, 2 x testo 549i high-pressure gauges, 2 x testo 605i thermohygrometers, testo HVAC softcase, In the kit: 2 x testo 115i clamp thermometers, 2 x testo 549i high-pressure gauges, testo Smart Case, Sprung thermocouple cross-band adapts to any surface, Convenient temperature measurement on refrigeration, air conditioning and heating systems thanks to wireless connection to your smartphone or tablet, Fast identification of temperature changes by graphic progression display, Perfect for checking surface temperatures, Extra wide measuring tip for placing on a flat measuring point, Non-contact temperature measurement, measurement of flow and return temperature as well as gas flow pressure, Measurement menu for pressure-drop test including alarm function, Smart Probe for wireless temperature measurement in a wide range of applications, thanks to a large selection of probes and compatibility with standard type K thermocouple probes, In the kit: testo 915 Smart Probe with secure locking mechanism for attaching probes, air probe, immersion/penetration probe and surface probe, (all TC Type K, Class 1), testo Smart Case, Simple, fast and particularly precise temperature measurement with NTC or Pt100 probes (optionally available), Easy, fast and precise differential temperature measurement with dual thermocouple Type K probes (2 TC Type K probes included), Measures manifold gas pressure, pressure drop, air flow, (with optional pitot tube), and pipe and radiator temperatures, Performs timed pressure leak-down tests on pipe systems, Super-fast reaction time / surface temperature sensor, Temperature measurement and direct display of differential temperature, Surface temperature probes with Velcro: enables easy attachment of the probe to pipes, Evaluate renovation measures quickly and flawlessly, Easy probe attachment, even in inaccessible places. For example, sensors may have none, two, or several options to choose from. Not every sensor has different cable termination options. NB1-ICIN_INDUST_TC, Learn more about the Maximize plant operating performance from start-up to shutdown with Emerson service technicians. LEARN MORE Keep Operations Running Smoothly with Accurate Road Condition Data Contact us to discover why why Vaisala's road and runway surface condition solutions are the industry's most trusted. General use fast response thermistor sensors mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 150C. Since infrared temperature sensors detect also visible steam or smoke, the measured temperature may include errors. Available in type J, K, T, or E calibrations. Housing Includes a Clearance Hole for a #4 Mounting Screw or Can be Cemented or Epoxied to Flat Bolt-On Thermistor Sensors with Threaded SS Housing. Some examples of sensors that fall into this category include the 107-L, 109SS-L, 229-L, CS547A-L, and CS650-L. For the process of returning equipment to Campbell Scientific, refer to the Repair and Calibration page. This requires that the sensor is connected to the instrument so that the signal can be received. Whether you are just getting started or looking to cover some of the blind spots in your current observation network, Vaisala GroundCast provides the road weather measurements that matter the most. Accurately sense and measure temperature, humidity and fluid levels across a wide range of applications. The surface temperature sensor's output is 4-20 mA with a two wire configuration. To detect the temperature of the windings of all phases, the PTC sensors should be connected in series. They offer smaller errors caused by lead wire resistance and high sensitivity among temperature sensors, relative to their cost. The temperature range is -50 to 200C (-58 to 392F). The following describes the types and characteristics of major contact-type temperature sensors. /* Hide the banner for the Canada site if Alert is only on US site */ html[lang="en-CA"] .alert-banner, html[lang="fr-CA"] .alert-banner { /*display: none !important;*/ } /* Apply look/feel changes to Alert messaging */ .alert-banner a { color: #fff; } .alert-banner a:hover { text-decoration: underline; } .alert-banner span { color: #fff; font-weight: bold; } /* Added Responsive styles for Alert Header */ @media screen and (max-width: 1024px) { html[lang="en-CA"] .alert-banner, html[lang="fr-CA"] .alert-banner { /*display: none !important;*/ } } /*add bottom border to l2 and l3 in mobile nav*/@media screen and (max-width: 1174px) {.main-menu .sub-level li.no-submenu .cat-level-two a, .main-menu .sub-level-two li .cat-level-three a {border-bottom:solid 1px #ddd;white-space: pre-wrap;}.main-menu .sub-level-two li .cat-level-three a{padding: 10px 20px;}}. Patented Spool Caddy Self Adhesive Backing for Easy Installation Better Than 0.3 Second Response Time 1 m (36") or 2 m (72") Color-Coded PFA Insulated Leads Rated to 175C (350F) Long Term Available in J, K, T, and E Calibrations Self-Adhesive Polyimide Fast Response Surface Thermocouples, IEC. Order: I2-45062 . Plastic molding: Temperature control of materials immediately before pouring. They are suitable for both surface mount and embedded applications. However, a compensation lead wire is required to extend the cable. The RTD sensor changes the electrical resistance with a change in temperature. Technical Resources View All Selection Guides The emissivity of objects in general falls somewhere between 0 and 1. Catalogs The sensing element is made of pure platinum encapsulated in ceramic insulation. Series I2-4 Weatherproof Immersion Temperature Sensor. Description: Skin Temperature Sensor with 400 Series Thermistor. Edit these specs to order a different model. Surface contact sensors, such as back-of-module sensors, attach directly to a surface and measure the temperature via physical contact. Some sensors have a user-specified cable length, whereas other sensors have a set cable length. They are suitable for the measurement of temperatures between -200 C and approx. The TMP117 is a high-precision digital temperature sensor. When a temperature sensor is used to measure the temperature around a target, it is possible to detect that the temperature has reached the upper or lower limit due to an abnormality with the air-conditioning system or to maintain optimum temperature control for the target. FT Series digital infrared temperature sensors are designed to provide wide temperature detecting ranges, high responsiveness, long detecting distances, and easy installation and settings. It has an aluminum housing for fast transfer of heat to/from the sensing element. For example, when a temperature sensor is set with the upper and lower limit temperatures to turn on/off the cooling equipment for the motor of a processing machine, the motor can be cooled with the appropriate timing when it gets hot due to excessive loads or other causes. , Spectral Interference Displacement Sensor, LVDT / Contact Displacement Sensors (Probes), Laser Marking Systems / Continuous Inkjet Printers, Industrial Continuous Inkjet Printers / CIJ Printers. Temperature Sensing Thermistors Littelfuse offers Surface Temperature Probe Assemblies suitable for a wide range of temperature sensing applications. With the help of the so-called thermocouples reference tables (see IEC 60584) the temperature at the connection (measuring junction) can be concluded. If the sensor head is heated by the radiant heat from the target and detection becomes inaccurate due to the high temperature of the thermopile inside, you can prevent the rise of the internal temperature by covering the sensor head with aluminum foil. If there is any heat source such as people, operating equipment, or a heater, setting the emissivity in accordance with the target will enable accurate measurement. Half of the sensors we produce are custom-engineered designs developed for challenging applications. Infrared temperature sensors are a non-contact means of measuring the surface temperature of an object or surface by sensing the infrared radiation given off by the subject. . These sensors provide accurate measurements of temperature with a digital output signal and small circuit board package. This instrument is described as the standard. In the PW (PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure. Sometimes, an old cable can be replaced with a new, longer cable. Starting at $67.00. Measuring surfaces, recording temperature on surfaces and all the other VAC parameters too! Using an infrared temperature sensor allows the prevention of problems such as those caused by low solder temperatures. Vernier Software & Technology is now Vernier Science Education! It can go up to about 145F before the motherboard temperature sensor shuts it down. What are the different cable termination options available for Campbell Scientific sensors? This means that the temperatures of workpieces during hot forging must be measured from a distant location where the sensors will not be affected by the heat. Make sure you are not blocking the airflow and try to keep it in the shade if outside.